Efficiency Results
|
300 Series Part Number |
Efficiency (A) |
MAX Flow GPM (B) |
| 93% |
96% |
| KHE 323P2SSL |
1 um |
2 um |
75 |
| KHE 325P2SSL |
3 um |
5 um |
75 |
| KHE 327P2SSL |
8 um |
18 um |
75 |
| KHE 329P2SSL |
18 um |
25 um |
75 |
| 500 Series |
Efficiency (A) |
MAX (B) |
| Part Number |
96% |
99% |
Flow GPM |
| KHE 523P2SSL |
1 um |
2 um |
50 |
| KHE 525P2SSL |
3 um |
5 um |
50 |
| KHE 527P2SSL |
8 um |
18 um |
50 |
| KHE 529P2SSL |
18 um |
25 um |
50 |
|
(A) Efficiency represents the initial efficiency on a clean element challenged on a single pass through a water base slurry of PT1 fines test dust at 3 GPM. Effieciencies are derived by counting the ratio of upstream versus downstream particles um = micron.
(B) Flow data based on gallons per minute (GPM) for 1 pound (PSID) of pressure across a clean filter.
|
|
|
Flow Results
|
 |
300 Series |
500 Series |
| Max Dirt Grams of Dust (C) |
1,200 |
2,042 |
| Max Total Filter Layers |
5 |
10 |
| Max Sq. Ft. Surface Area |
23 |
43 |
| Quantity Per Large Box |
20 |
10 |
| Max Temperature |
200 F |
200 F |
| Felt and Microfiber Sections |
Yes |
Yes |
| Easy Lift Handles |
Yes |
Yes |
| Silicone Free |
Yes |
Yes |
| No Exposed Sewn Seams |
Yes |
Yes |
| Oil Absorption and Removal |
Yes |
Yes |
| Batch Operations |
Yes |
Yes |
| Continuous Operations |
Yes |
Yes |
| Pure Polypropylene Media |
Yes |
Yes |
|
(C) Dirt load conducted until vessel pressure reached 40 pound (PSID).
|
Knight Corporation believes laboratory generated performance data is a useful tool for
comparing different micron ratings and as a guide for establishing a recommendation
in a filtering application. However, this data should not be construed as a guarantee or
warranty by Knight Corporation, either expressed or implied, of a specific
performance from use of our product. Due to variances in fluid viscosity, temperature,
velocity, pressure and contaminant size, shape and texture, Knight Corporation cannot
guarantee field results equaling test results.
|