inc.   ·  · · · Technical alterations reserved (Date 1/99) Prefiltered and clean air and dried compressed air (required inlet conditions) is led via the inlet (1) into the vessel and gets through the gas diffuser at the adsorption vessel inlet (2) and through the activated carbon bed (3) from top to bottom. In the activated carbon bed, the compressed air cleaned from oil vapors and hydrocarbons. The cleaned air is led via the lower gas diffuser (4) and the oulet of the adsorption vessel (5) to the compressed air network and to the point of use. By means of an oil indicator at the outlet of the adsorber (6), the saturation of the carbon can be measured online, at any time. ultrasorp AKC Type 0005 to 8750 Activated carbon adsorber with residual oil indicator Activated carbon adsorber – AKC AKC Volume flow Pressure loss in initial cfm* psi 0005 3 0.14 0010 5 0.14 0015 10 0.22 0025 15 0.22 0035 20 0.36 0050 30 0.22 0080 50 0.72 0100 60 0.72 0150 85 0.72 0225 125 0.58 0300 175 0.58 0375 200 0.87 0550 300 0.87 0650 400 1.00 0850 500 1.30 1000 600 0.87 1350 800 0.87 1650 1000 0.79 1950 1200 0.58 2250 1400 0.72 2750 1600 0.87 3500 2000 1.00 4000 2400 0.65 5000 3000 0.72 6000 3500 0.87 7000 4000 0.64 8750 5000 0.65 * related to 14.7 psi (abs) and 68 °F at intake of compressor and 100 psig system pressure and 100 °F inlet temperature into adsorber 1 2 3 4 5 6
Please contact Filter Products at 804-231-4646 to place an order or for more information about this product.