Technical alterations reserved (Date 1/99)
Prefiltered and clean air and dried
compressed air (required inlet conditions)
is led via the inlet (1) into the vessel
and gets through the gas diffuser at the
adsorption vessel inlet (2) and through
the activated carbon bed (3) from top
to bottom. In the activated carbon bed,
the compressed air cleaned from oil
vapors and hydrocarbons.
The cleaned air is led via the lower gas
diffuser (4) and the oulet of the adsorption
vessel (5) to the compressed air network
and to the point of use.
By means of an oil indicator at the outlet
of the adsorber (6), the saturation of the
carbon can be measured online, at any
time.
ultrasorp AKC
Type 0005 to 8750
Activated carbon adsorber with residual oil indicator
Activated carbon adsorber
AKC
AKC
Volume flow
Pressure loss
in
initial
cfm*
psi
0005
3
0.14
0010
5
0.14
0015
10
0.22
0025
15
0.22
0035
20
0.36
0050
30
0.22
0080
50
0.72
0100
60
0.72
0150
85
0.72
0225
125
0.58
0300
175
0.58
0375
200
0.87
0550
300
0.87
0650
400
1.00
0850
500
1.30
1000
600
0.87
1350
800
0.87
1650
1000
0.79
1950
1200
0.58
2250
1400
0.72
2750
1600
0.87
3500
2000
1.00
4000
2400
0.65
5000
3000
0.72
6000
3500
0.87
7000
4000
0.64
8750
5000
0.65
* related to 14.7 psi (abs) and 68 °F at intake