ultrafilter inc.   · · · · Refrigeration Compressed Air Dryer BOREAS Technical data BOREAS SD 1950 A - SD 8750 A (60 Hz-Version) SD1950 1 R 134 a 1200 6100 3.78 2.76 4" 3/4" 47.24 74.8 49.41 948 SD2250 1 R 134 a 1400 6100 4.44 2.76 4" 3/4" 47.24 74.8 49.41 992 SD2750 1 R 134 a 1600 6100 4.68 3.6 4" 3/4" 47.24 74.8 49.41 1014 SD3500 1 R 134 a 2000 5800 6.84 2.46 6" 3/4" 47.24 74.8 49.41 1322 SD4000 1 R 134 a 2400 5800 7.56 3.2 6" 3/4" 47.24 74.8 49.41 1345 SD5000 1 R 134 a 3000 5800 9.84 3.6 6" 1" 47.24 74.8 49.41 1422 SD7000 2 R 134 a 4000 12000 14.64 3.6 8" 1" 87.6 74.8 49.41 2227 Typ cfm cfm kW V/60Hz psi 150 lbs NPT inch inch inch lb 3 / 460 V Designation 1   Housing version 2   Refrigerant 3   Volume flow 4   Cooling air required 5   Power consumption 6   Mains voltage 7   Pressure drop 8   Air connections (Ansi) 9   Condensate drain 10   Main Width W dimensions Height   H Depth    D 11   Weight SD8750 2 R 134 a 5000 11500 17.4 3.8 8" 1" 87.6 74.8 49.41 2602 Low pressure drop due to large flow channels Pollution repellent aluminium plates Cyclone separator Microprocessor controlled zero loss drain SAB-Processor SP 3 Constant pressure dew point by means of thermostatic expan- sion valve and power control Electronic control of major functions by state-of-the-art technology Space-saving installation by front operating elements, conden- sate drain and cooling air inlet Application of solid, fully hermetic refrigerant compressors Galvanised, stove-enamel sheet steel case in modern industrial design No TÜV-approval required The electrical installation is carried out in accordance with EN 60204, all technical data comply with CAGI ADF 100. Safety regulations are in accordance with the regulations for prevention of accidents UVV VBG 20. Low running cost Eco-friendly refrigerant R 134a C UL approval Technical data comply with CAGI ADF 100 Modular construction Optional: Energy saving device (Standby mode for zero load operation) W D H s Cooling air outlet Cooling air inlet Compressed air inlet Compressed air outlet BOREAS DSM – significant advantages: -  Fully hermetic and maintenance-free refrigerant compressor -  Air cooled condenser -  Aluminium air/air and refrigerant/air-heat exchanger -  Maintenance-free separator -  Electronically level-controlled condensate drain, ultramat -  Refrigerant capacity control -  Thermostatic expansion valve -  Insulation free of CFC -  Galvanised, stove-enamel sheet steel case -  Dry contact for generel alarm -  Dry contact for dew point alarm -  Working hour meter Item 3: Volume flow referred to suction status of the air compressor +68°F, 14.5 psi g, compressed air inlet temperature +100°F, operating pres- sure 100 psi g, pressure dew point +35°F - at dryer outlet  Item 5: Power consumption at an ambient temperature of +100°F Standard version air cooled · Permissible ambient temperatures: min. +36°F, max. +122° F · Max. permissible operating pressure: 232 psi g, higher pressures on request · Protection class: IP 54 · Sound pressure level: dB(A) < 80 · Technical data in according to CAGI ADF 100. Specifications are subject to change without notice. Standard equipment
Please contact Filter Products at 804-231-4646 to place an order or for more information about this product.