Refrigeration Compressed Air Dryer BURAN ultrafilter inc.   · · · · How the BURAN works? Compressed air is fed into the dryer and  is  precooled  in  the  air-to-air  heat exchanger by the outgoing cold compressed air. The precooled air then passes through the refrigerant-to-air heat exchanger where 1 2 3 8 7 6 5 4 10 9 B U R A N REFRIGERATION DRYER   1   Compressed-air inlet   2   Compressed-air outlet   3   Air-to-air heat exchanger   4   Refrigerant-to-air heat exchanger   5   Condensate separator   6   Microprocessor con- trolled condensate drain   7   Hermetically sealed refrigerant compressor   8   Refrigerant condenser   9   Thermostatic expansion valve 10   Refrigerant controller The ultratroc advanced concept for drying compressed air At ultratroc, energy saving has always been important, but now the BURAN range comes with a new energy saving control that thinks for itself. During longer periods of zero-load the dryer automatically shifts to  stand-by  operation  using  the  TRISAB heat exchanger as a cold storage mass. This results in minimum power consumption while maintaining a constant availability of the dryer. The CFC free heavily insulated TRISAB heat exchanger with its high material density acts as a thermal mass, and will provide  effective  compressed  air  drying capacity  across  a  wide  and  fluctuating range  of  compressed  air  flow.  Electrical power  consumption  is  remarkably  low. Refrigerant  gas  charge  is  low  and  only environmentally  friendly  R  134  a  gas  is used.    No    air    loss    microprocessor condensate  drains  are  now  fitted  as standard. it is further cooled to the required pressure dew  point  (usually  38°F  or  41°F,  above which temperature moisture will not form in the compressed air system). The moisture in the compressed air condenses out and is collected and discharged automatically. Finally,  the  cold  discharged  air  is rewarmed by the incoming compressed air. This  saves  energy  and  prevents  any moisture forming beyond the dryer in the compressed air system. Standard equipment -    Complete refrigeration system with fully hermetic refrigerant compressor -    Energy-saving stand-by operation (from SD 0225) -    Maintenance free separating system -    Refrigerant and oil filling -    Microprocessor controlled condensate drain, system ultramat -    Zinc coated varnished sheet steel housing -    Pressure dew point indicator -    Operating switch with signal lamp Options: -    By-pass line -    Potential free alarms -    Designs for special voltages -    Watercooling from model SD 0550 -    Microprocessor monitoring and control systems from model SD 0550
Please contact Filter Products at 804-231-4646 to place an order or for more information about this product.